Process Validation of Existing Processes and Systems Using Statistically Significant Retrospective Analysis

 Uncategorized  Comments Off on Process Validation of Existing Processes and Systems Using Statistically Significant Retrospective Analysis
Oct 162016
 

Process Validation of Existing Processes and Systems Using Statistically Significant Retrospective Analysis – Part One of Three

 

The FDA defined Process Validation in 1987 by the following: “Process Validation is establishing documented evidence which provides a high degree of assurance that a specific process will consistently produce a product meeting its predetermined specification and quality attributes.” 1The purpose of this article is to discuss how to validate a process by introducing some basic statistical concepts to use when analyzing historical data from Batch Records and Quality Control Release documents to establish specifications and quality attributes for an existing process. In an ideal world, the qualification of processing equipment, utilities, facilities, and controls would commence at the start up of a new plant or the implementation of a new system. This would be followed by the validation of the process based on developmental data and used to establish the product ranges for in process and final release testing. However, the ideal case may not exist and thus there are incidences where commissioning of facilities or new systems occurs concurrently with the qualification and process validation; or the facility and equipment are “existing” and there is no such documentation. Some facilities, equipment, or processes pre-date the above definition by many years and therefore have never been validated on qualified equipment, utilities, facilities, and controls. Additionally, in some cases, no developmental data exists to establish the product ranges for in process and release testing.

Basics of Process Validation

Before examining the existing processes, it is important to first understand the basic concepts of Process Validation. Figure 1 is a flow chart defining Process Validation from the developmental stage to the plant floor. As a simplistic example, a process begins with the raw materials being released, then the raw materials are mixed, pH is adjusted, purification occurs by gel chromatography, excipients are added for final formulation, and the product is filled and terminally sterilized. Each of these steps has defined functions and therefore would have a designed goal. For example, purification would not begin until the desired pH is reached in the previous step. Therefore, the desired pH is an in process attribute of the pH adjustment stage and the amount of buffer used to adjust the pH is a processing parameter. Each of these steps has attributes that one would want to monitor to determine that the product is being produced acceptably at that step such that the next process step can start. The ranges for these attributes are generally determined by process development data so that if the process attributes are met, then there is a high degree of confidence that the final container is filled with a product of acceptable attributes as determined by the developmental data.

Click on image for larger view

During Process Validation, there needs to be approved Standard Operating Procedures (SOPs) in place that Plant Operators have been trained on. Analytical testing should be performed by SOPs and the Quality Control (QC) analysts should be trained in these SOPs as well. The analytical tests should have been previously validated by normal analytical methods validation and documented as such. Also, the equipment used to prepare product must be documented to be qualified for its installation, operation, and performance, commonly referred to as IQ, OQ, and PQ. There are methods for performing such qualification retrospectively, but for the purpose of this discussion, it is only important to note that the equipment must be qualified.

Relating Process Validation to Existing Processes

Existing processes may lack developmental data for in process ranges and release testing. If a retrospective analysis of existing data is used to establish process ranges, including input, output, and in process testing parameters, then the process can be treated like a new process by following the basics of Prospective Process Validation. The difference between traditional Prospective Process Validation and Prospective Process Validation based on retrospective analysis is that in place of developmental data to establish ranges, the retrospective analysis reviews data from past Batch Production Records, QC test reports, product specs, etc. Thus the items that need to be in place are: approved SOPs, and Batch Records with personnel training, equipment qualification (IQ, OQ, PQ), QC methods validated, approved SOPs and training for QC personnel. With these in place, all that is missing is a Process Validation Protocol with defined ranges. The best sources of this information are approved completed batch records, process deviation reports, QC Release data, and small-scale studies. From these, the following items must be completed:

  • Critical parameters and input and output parameters must be defined.
  • A statistically valid time frame or number of batches must be determined.
  • The data used to establish the parameters must be extracted from controlled documents.
  • The data extracted from the controlled documents will be analyzed to establish ranges.

Each one of these steps will be examined in the following sections to describe them in further detail.

Critical parameters and input and output parameters defined.

In The Guidelines on General Principles of Process Validation, 15 MAY 1987, it states that:

The validity of acceptance specifications should be verified through testing and challenge of the product on a sound scientific basis during the initial development and production phase.1

It is important to determine which parameters in your process are critical to the final product. When determining these parameters and attributes a variety of personnel with different expertise should be utilized. Assembling a team of professionals is a starting point and this committee should be a multi-disciplined team including Quality, Validation, Systems Engineering, Facility Engineering, Pharmaceutical Sciences (or R&D), and Manufacturing. When determining the parameters and attributes which are critical, it is important to consider those which if they were not controlled or achieved, then the result would have an adverse effect on the product. A risk assessment should be performed to analyze what the risk is and what the results are if a specific parameter or attribute is not controlled or achieved (e.g. the resulting product would be flawed). Risk assessment is defined by The Ontario Ministry of Agriculture, Food and Rural Affairs as:

  1. the probability of the negative event occurring because of the identified hazard,
  2. the magnitude of the impact of the negative advent, and
  3. consideration of the uncertainty of the data used to assess the probability and the impact of the components. 2

Click on any image for larger view

Figure 2 is a list of general questions to consider when assessing risk while Figure 3 is an example of Fault Tree Analysis – a formal approach to evaluating risk, where a Top Level Event is observed and through questions and observations the cause of the event can be determined.

National Center for Drugs and Biologics and National Center for Devices and Radiological Health, “Guidelines on General Principles of Process Validation,” Rockville MD. 15 MAY 1987.National Center for Drugs and Biologics and National Center for Devices and Radiological Health, “Guidelines on General Principles of Process Validation,” Rockville MD. 15 MAY 1987.Ontario Ministry of Agriculture, Food and Rural Affairs (2000), Queen’s Printer for Ontario, Last Updated March 22, 2000; WEB:http://www.gov.on.ca/omafra/english/research/risk/assum1b.html.

Process Validation of Existing Processes and Systems Using Statistically Significant Retrospective Analysis – Part Two of Three

 

A Statistically Valid Time Frame or Number of Batches

How large of a sample set is needed of previously recorded data to determine ranges that are truly representative of the process, and will the ranges be useful in the Validation effort and not set one up for failure? This is a difficult question to answer, and it is important to note that the batches selected should have no changes between them, thus be produced with the same processing conditions. The draft FDA Guidance for Industry, Manufacturing, Processing, or Holding Active Pharmaceutical Ingredients from March of 1998 suggests that 10-30 consecutive batches be examined to assess process consistency. 1

This is a good target statistically because when selecting a sample size or population, the concept of Normality or Degree of Normality becomes important. As a general rule of thumb, the population should be large enough that the distribution of the samples within the population approaches a Normal or Gaussian distribution (one defined by a bell-shaped curve). Thus in theory if the samples are normally distributed then 99% of the samples will fall within the +/- 3 Standard Deviation (S.D.) range. 2 When considering this, one should think in the sense of Statistical Significance (the P-Value). The P-Value is the significance that a given sample will be indicative of the whole population. Thus at 99% (a P-Value of 0.01) then a given sample has 1% chance of falling outside the +/- 3 S.D. range or (assuming no relationship with other variables) the sample has a 99% statistical significance as representative of the population. Finally, when considering the central limit theorem, which has the underlying concept that as the sample size gets larger, the distribution of the population becomes more normal, then in general a sample size of 10 – 30 as the FDA suggests would have a high chance of being distributed normally.

The data used to establish the parameters must be extracted from controlled documents.
When the number of batches to review is selected, the next step is to determine from what documents the processing data will be extracted. Typically the range establishing data must be taken from approved and controlled documents (see the examples below).

Examples of Controlled Documents:

  • Batch Production Records (BPRs)
  • Quality Control (QC) Lab Reports
  • Limits establish by Licensure
  • Product License Agreement (PLA)
    – Biologic License Agreement (BLA)
    – New Drug Application (NDA) or Abbreviated (ANDA)
  • Product Release Specifications
  • Small scale bench studies simulating plant environment.

The data extracted from the controlled documents will be analyzed to establish ranges.
Having established where the data will be selected from, the data must then be analyzed for specific trends such to define ranges for the Process Validation Protocol’s acceptance criteria. This acceptance criteria will be what the “Actual” process data collected during the execution of the Protocol will be compared to, in order to verify its acceptance. This part is where much thought needs to be applied so that the acceptance criteria are not so tight that failure is eminent or so broad that the achievement of the criteria proves nothing. Listed below are general steps that can be incorporated to determine the analysis.

  1. Draw “X Charts” and analyze for outliersApply a model to determine Normality
  2. Determine the +/- 3 S.D. range and plot on Trend Chart
  3. Determine the Confidence Interval as compared to +/- 3 S.D.
  4. Process Capability Indices
  5. Recording the Maximum and Minimum
  6. Assign Acceptance Criteria Range and justify

Drawing Trend Charts

Trend Charts, also referred to as X-Charts, are a good way of plotting data points from a set of data where the target is the same metric (for example pH as measured at a specific point in the process). It is a matter of defining the X-axis by the number of samples and the Y-axis by the metric that is being used. As an example, the X-axis could be a list of the batches by batch number and the Y axis could be pH. Figure 4 is an example of a type of trend chart. This way the data is presented graphically and can be appreciated with respect to setting a range.

With the data plotted, one can quickly assess any visible trends in the data. Additionally one can no begin the task of applying statistics to the data. It is important to determine if there are outliers in the data. Outliers may exist and can usually be rationalized by adverse events in processing as long as they are reported appropriately. Outliers can also exist as samples that are “statistically insignificant.” As mentioned before, the P-Value is the significance that a given sample will be indicative of the whole population so that outliers would have a very low P-Value. One method for determining outliers is to use a box-plot where a box is drawn from a lower point (defined typically by the 25th percentile) to an upper point (typically the 75th percentile). The “H-spread” is defined as the distance between the upper and lower points. 3 Outliers are then determined to be any data that falls outside a predetermined multiplier of the H-spread. For example the lower outlier limit and upper outlier limit are defined as 4 times the H-Spread, anything above or below these limits is statistically insignificant and are outliers.

Apply a model to determine Normality

With the accumulated data plotted, the Degree of Normality should be investigated so that the data can be analyzed by the appropriate method. There are several models for determining the Degree of Normality; some common ones are the Kolmogorov-Smirnov test, Chi-Square goodness-of-fit test, and Shapiro-Wilks’ W test. 4 Once the Degree of Normality is determined a more appropriate statistical method can be applied for setting ranges. If the data is determined to be non-Normal than there are two approaches to evaluating the data. The first way is to apply a Nonparametric Statistical model (e.g. the Box-Cox Transformation 5 ), however, these tests are considered to be less powerful and less flexible in terms of the conclusions that they provide, so it is preferred to increase the sample size such that a normal distribution is approached. 5 If the data is determined to be Normal or the sample size is increased such that the data is distributed more normally, then the data can be better analyzed for it’s range characteristics.

Click on any image for larger view

Determine the +/– 3 SD range and plot on Trend Chart

The data having now been displayed graphically should be analyzed mathematically. This can be done by using simple statistics where the mean is determined as well as the standard deviation. The mean refers to the average of the samples in the population. The standard deviation is the measure of the variation in the population from the mean. If the distribution proves to be normal, as from our normality tests above or by selecting a large enough population such that the central limit theorem predicts the distribution to be normal, then it stands that 99% of the data will fall within the +/–3 SD range. Using our example from Figure 4, the data is analyzed for its mean and standard deviation using the displayed formulas in Figure 5. Once this is determined, the +/– 3 SD can be applied to the trend charts by drawing them as limits at their values. This graphically displays the data as it is applied per batch and how it fits within the statistical limit of +/– 3 SD (see Figure 6.)

  1. U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, Guidance for Industry, Manufacturing, Processing, or Holding Active Pharmaceutical Ingredients, March 1998, 36
  2. StatSoft, Inc. (1999). Electronic Statistics Textbook. Tulsa, OK: StatSoft. WEB: http://www.statsoft.com/textbook/stathome.html
  3. Rice Virtual Lab in Statistics (1993-2000), David M. Lane, HyperStat Online, Houston TX, WEB:http://www.ruf.rice.edu/~lane/rvls.html
  4. StatSoft, Inc. (1999). Electronic Statistics Textbook. Tulsa, OK: StatSoft. WEB: http://www.statsoft.com/textbook/stathome.htm
  5. Box, G.E.P., and Cox, D.R. (1964), “An Analysis of Transformations,” J. Roy. Stat. Soc., Ser. B.

 

Process Validation of Existing Processes and Systems Using Statistically Significant Retrospective Analysis – Parts Three of Three

 

Determine the Confidence Interval as compared to +/- 3S.D. With the +/- 3 S.D. ranges determined, it can be considered important to evaluate what confidence there is that the next data point will fall within this range. The rationale for determining this level is to justify that the +/- 3 S.D. range provides a confidence that 99% of the data is within that range. Similar to the +/- 3 S.D. range, the confidence interval is a range between which the next measurement would fall. This level is typically 99% or greater. Thus a 99% confidence interval means, “there is 99% insurance that the next value would be in the range.” To calculate a 99% Confidence Interval, one needs to consider the area under the standard normal curve, the mean, the standard deviation, and the population size. Determining this level can be done using the formula in Figure 7. The confidence interval can be added to our previous example and is displayed in Figure 8.

Figure 8: Trend Chart with +/- 3 S.D. and Confidence Interval.

Figure 7: Definition of Confidence Interval Formulas.

Following our example:

Confidence Interval (99.9%) = 6.23 ± snc ( 0.151202/(30) 1/2)

Confidence Interval (99.9%) = 6.95 to 6.02

The confidence interval at 99.9% is slightly more narrow than the +/- 3 S.D. range which follows the trend if the +/- 3 S.D. range provides that 99% of the data will be within the range if the data is normally distributed.

As can be seen in the trend charts, the data fits well within the +/- 3 S.D. range, and therefore the confidence level is very high that the next data point that is collected will be within this range. Therefore this range may be appropriate to use as acceptance criteria based on the statistics. If the confidence level was wider than the +/- 3 S.D., then the data would have to be analyzed such to investigate if there were errors in calculating the degree of normality, the +/- 3 S.D., the confidence level, the outliers, or errors in the sampling technique to show that it was not computational error.

Process Capability Factors

Another method to setting ranges to be used as acceptance criteria are the Process Capability Indices defined by:

CPu = (USL – µ) / s (or in our example 3 S.D.)

CPl = (µ – LSL) / s (or in our example 3 S.D.)

Where:

USL = Upper Specification Limit

LSL = Lower Specification Limit

An industry accepted standard CP would be 1.33.1 This would mean that only 0.003% of the testing results would be out of the specification or 99.997% would be within the specification. This is a similar concept to confidence level.

Recording the Maximum and Minimum

Recording the maximum and minimum values in the data is important because it is a quick way to see if the data is all within the +/- 3 S.D. range. Additionally, if the maximum and minimum are within the +/- 3 S.D. range, than there is an additional level of confidence since all of the data would be within the range. Lastly, the data may be determined to be non-normally distributed and in such case, confidence may predict to high a possibility for failure at the +/- 3 S.D. range so in the interim, the maximum, and minimum values can be selected to be the range until further data can be collected to define the range (this refers back to increasing the sample size in order to approach a more normal distribution).

Assign Acceptance Criteria Range and Justify

Using all of the above analysis techniques, knowledge of the process and agreement on by a cross-discipline committee, acceptance criteria ranges can be assigned for the critical parameters and attributes. A general course of action would be to start by recording all the data at a given point in a spreadsheet, calculating the mean, S.D., population size, +/- 3 S.D., 95% and 99% confidence intervals, plotting the trend charts with appropriate ranges, and then deciding on which range makes the best sense. When selecting the acceptance criteria, a cross-functional committee should be utilized with backgrounds of QA, Manufacturing, Validation, R&D, and Engineering present. The

ranges should be selected and justified by scientifically sound data and conclusions. The ranges should be within the PAR for the product, which means that if +/- 3 S.D. is selected, the range should be checked at the upper and lower limits to verify that acceptable product is prepared. This should be done prior to a final agreement on the range and incorporation into the validation protocol. A report should be written to document the ranges with the rationale for selecting them and the justification for determining the limits as well as any determination that the ranges are within the PAR. Additionally, those ranges which are not to be included should be discussed within the report to justify why they are not to be recorded. A process validation protocol should be prepared with theses ranges for acceptance criteria and the process should be run at a target within the acceptance criteria ranges at least three consecutive times using identical procedures to verify that the process is valid.

Summary

Since the ideal case of validating a process during its implementation does not always exist in the pharmaceutical, biopharmaceutical, biotechnology or medical device industries, it may be important to determine a way to validate these processes using historical data. The historical data can be found in a variety of places as long as it is approved (e.g. approved and completed BPRs or quality control release documents, etc). A cross-functional team should perform a risk assessment on the parameters and attributes to determine which ones would be included in the process validation. A range establishing study for the attributes and parameters should be performed to evaluate historical data and analyze the data set for the concepts of normality, variation (standard deviation), and confidence. With a high degree of confidence, acceptance criteria ranges should be set for each parameter and attribute and a process validation protocol should be written with the appropriate ranges. This protocol should be approved and executed at target settings within the acceptance criteria ranges, from the start of the manufacturing process to the finish using qualified equipment, approved SOPs, and trained operators. In a final report for the process validation, the degree to which the process is valid would be determined by the satisfaction of the approved acceptance criteria.

References

1. Box, G.E.P., and Cox, D.R. (1964), “An Analysis of Transformations,” J. Roy. Stat. Soc., Ser. B., 26, 211.

2. Kieffer, Robert and Torbeck, Lynn, (1998), Pharmaceutical Technology, (June), 66.

3. Lane, David M., Rice Virtual Lab in Statistics (1993-2000), HyperStat Online, Houston TX, WEB: http://www.ruf.rice.edu/~lane/rvls.html.

4. National Center for Drugs and Biologics and National Center for Devices and Radiological Health,(1987) “Guidelines on General Principles of Process Validation,” Rockville MD. 15 MAY.

5. Ontario Ministry of Agriculture, Food and Rural Affairs (2000), Queen’s Printer for Ontario, Last Updated March 22, 2000; Web: http://www.gov.on.ca/omafra/english/research/risk/assum1b.html.

6. StatSoft, Inc. (1999). Electronic Statistics Textbook. Tulsa, OK: StatSoft. WEB: http://www.statsoft.com/textbook/stathome.html.

7. U.S. Department of Helath and Human Service, Food and Drug Administration, Center for Drug Evaluation and Research, Center for Biologics Evaluation and Research, Center for Veterinary Medicine, “Guidance for Industry: Manufacturing, Processing, or Holding Active Pharmaceutical Ingredients,” Rickville MD. March 1998, 36.

 

//////////Process Validation,  Existing Processes and Systems, Retrospective Analysis

Share

Current Practices of Process Validation for Drug Substances and Intermediates

 PROCESS, regulatory  Comments Off on Current Practices of Process Validation for Drug Substances and Intermediates
Jan 132016
 
Abstract Image

Process validation includes laboratory optimization, pilot-plant introduction, and process implementation on manufacturing scale, as well as monitoring batches after implementation and continuously improving the manufacturing processes. There are many opportunities to change and optimize operations. The background information in this contribution describes current guidance and terminology for validation, including the integration of validation over the development lifecycle of drug substances. Various examples illustrate challenges and success stories of implementation as part of the overall approach to process validation.

 

Current Practices of Process Validation for Drug Substances and Intermediates

Anderson’s Process Solutions, 7400 Griffin Lane, Jacksonville, Oregon 97530, United States, Creative Innovation Partners, 1971 Western Avenue, Albany, New York 12203, United States, and Rib-X Pharmaceuticals Inc., 300 George Street, New Haven, Connecticut 06511, United States
Org. Process Res. Dev., 2011, 15 (1), pp 162–172
DOI: 10.1021/op1002825
Publication Date (Web): December 21, 2010
Copyright © 2010 American Chemical Society
* To whom correspondence should be addressed: E-mail: nganderson@dishmail.net., †

Creative Innovation Partners., ‡Rib-X Pharmaceuticals Inc.

http://pubs.acs.org/doi/abs/10.1021/op1002825

////////

Share
Follow

Get every new post on this blog delivered to your Inbox.

Join other followers: