AUTHOR OF THIS BLOG

DR ANTHONY MELVIN CRASTO, WORLDDRUGTRACKER

New Warning Letter of the FDA with the Focus on “Data Integrity”

 regulatory  Comments Off on New Warning Letter of the FDA with the Focus on “Data Integrity”
Sep 092016
 

The FDA has set the focus of its inspections on data integrity for quite some time already. The most recent Warning Letter addressed to a Chinese API manufacturer dated August 2016 clearly concentrates on the topic data integrity. Please find out more about the current FDA Warning Letter in this News.

http://www.gmp-compliance.org/enews_05557_New-Warning-Letter-of-the-FDA-with-the-Focus-on-%22Data-Integrity%22_15488,15844,Z-QCM_n.html

Again, the focus of FDA’s Warning Letter for the Chinese API manufacturer Zhejiang Medicine Co. Ltd. dated 4th August 2016 is on the lack of data integrity. Among other things, records of activities were made not at the time when they have been performed. Moreover, original data have been deleted. A number of alarming findings were discovered in the course of the FDA inspection in June 2015.

The FDA is now expecting concrete measures (“Data Integrity Remediation”) from the company. For this, the FDA expressly recommended to retain qualified, external consultants. Among the measures to be taken:

A – A comprehensive investigation of the extent of incorrect data
1. An extensive plan for the execution of the investigation
2. Interviews of current and former employees to clarify the root cause of incorrect data
3. An assessment of the extent of data integrity deficits.
4. A comprehensive retrospective assessment of the performance of analytical testing.

B – A current risk assessment of the possible effects of the deficiencies identified on the quality of the medicinal products, up to the risk to patients!

C – A management strategy for the implementation of CAPA plans.

All in all, there were great concerns about the authenticity and reliability of the data produced in that company.

To find out more access the complete Warning Letter for Zhejiang Medicine Co. Ltd.

Image result for Zhejiang Medicine Co. Ltd,

//////////Zhejiang Medicine Co. Ltd, Warning Letter,  FDA, Data Integrity

Share

New FDA Draft Guidance ‘Data Integrity and Compliance with cGMP’ published

 regulatory  Comments Off on New FDA Draft Guidance ‘Data Integrity and Compliance with cGMP’ published
Apr 292016
 

In the last years, the topic “data integrity” has become a priority for the FDA. Recently, the Agency has published the draft of a Guidance for Industry on the topic which presents the comprehensive opinion of the FDA on data integrity. Read more about the draft of the Guidance for Industry “Data Integrity and Compliance with cGMP”.

http://www.gmp-compliance.org/enews_05311_New-FDA-Draft-Guidance–Data-Integrity-and-Compliance-with-cGMP–published_15555,15527,15062,15064,Z-COVM_n.html

In recent years, the topic “data integrity” has become a priority for European and American inspectors. At the beginning of 2015, the British authority MHRA published a first paper on that topic. Also in 2015, the World Health Organisation WHO issued another significant draft document on data integrity. Recently, the US American FDA has released the draft of a Guidance for Industry entitled “Data Integrity and Compliance with cGMP”. Although the FDA describes the Guidance as a non-binding recommendation, one may assume that the document presents the current thinking of the FDA regarding the topic.

The FDA criticises the fact that more and more cGMP deficiencies with regard to data integrity have been observed during inspections. Those deficiencies have led to a number of follow-up measures like Warning Letters or import alerts.

For the FDA, the integrity of data is one of the main quality issues. In the Guidance, the corresponding reference points in parts 21 CFR 211 and 21 CFR 212 are listed in detail as well as the principles for electronic records laid down in 21 CFR Part 11.

  • § 211.68 (requiring that “backup data are exact and complete,” and “secure from 48 alteration, inadvertent erasures, or loss”)
  • § 212.110(b) (requiring that data be “stored to prevent deterioration or loss”)
  • §§ 211.100 and 211.160 (requiring that certain activities be “documented at the time 51 of performance” and that laboratory controls be “scientifically sound”)
  • § 211.180 (requiring that records be retained as “original records,” “true copies,” or 53 other “accurate reproductions of the original records”)
  • §§ 211.188, 211.194, and 212.60(g) (requiring “complete information,” “complete 55 data derived from all tests,” “complete record of all data,” and “complete records of 56 all tests performed”).

The most important topics for the FDA are presented in the quite rare but not unusual form of questions and answers. The document contains 18 questions with their respective answers.

1. Clarification of terms
– What is “data integrity”?
– What is “metadata”?
– What is an “audit trail”?
– How does FDA use the terms “static” and “dynamic” as they relate to record formats?
– How does FDA use the term “backup” in § 211.68(b)?
– What are the “systems” in “computer or related systems” in § 211.68?
2. When is it permissible to exclude CGMP data from decision making?
3. Does each workflow on our computer system need to be validated?
4. How should access to CGMP computer systems be restricted?
5. Why is FDA concerned with the use of shared login accounts for computer systems?
6. How should blank forms be controlled?
7. How often should audit trails be reviewed?
8. Who should review audit trails?
9. Can electronic copies be used as accurate reproductions of paper or electronic records?
10. Is it acceptable to retain paper printouts or static records instead of original electronic records from stand-alone computerized laboratory instruments, such as an FT-IR instrument?
11. Can electronic signatures be used instead of handwritten signatures for master production and control records?
12. When does electronic data become a CGMP record?
13. Why has the FDA cited use of actual samples during “system suitability” or test, prep, or equilibration runs in warning letters?
14. Is it acceptable to only save the final results from reprocessed laboratory chromatography?
15. Can an internal tip regarding a quality issue, such as potential data falsification, be handled informally outside of the documented CGMP quality system?
16. Should personnel be trained in detecting data integrity issues as part of a routine CGMP training program?
17. Is the FDA investigator allowed to look at my electronic records?
18. How does FDA recommend data integrity problems identified during inspections, in warning letters, or in other regulatory actions be addressed?

Source: FDA Draft Guidance for Industry “Data Integrity and Compliance with cGMP”

 

 

 

\//////////New FDA Draft Guidance, Data Integrity, Compliance, cGMP,  published

Share
Follow

Get every new post on this blog delivered to your Inbox.

Join other followers: